Module 1 | PSE&G AT Orientation | |
---|---|---|
Unit 1 | Orientation: How to get the most out of the PSE&G Advanced Troubleshooting Course | |
Module 2 | Basic Electricity Review | |
Unit 1 | Basic Electricity and Circuits | |
Unit 2 | Electrical Measurements Overview | |
Unit 3 | Using Ohm's Law as a Powerful Troubleshooting Tool | |
Module 3 | Fundamental Troubleshooting Techniques | |
Unit 1 | Troubleshooting and the Ten-Step Tango | |
Unit 2 | Guidelines for Reading Schematics | |
Unit 3 | Special Situations and Techniques | |
Module 4 | Schematic Reading Exercises | |
Unit 1 | Schematic Exercises: Appliances with Electronic Control Boards A | |
Unit 2 | Schematic Exercises: Appliances with Electronic Control Boards B | |
Module 5 | Troubleshooting Appliances with Timer Charts | |
Unit 1 | Analyzing Dryer Timer Motor Operation Using EEPs and the Timer Chart | |
Module 6 | Troubleshooting Appliances with Electronic Control Boards | |
Unit 1 | Troubleshooting Distributed vs. Central Control Systems | |
Unit 2 | Troubleshooting Appliances with Multiple Control Boards | |
Module 7 | Gas Dryer Technology | |
Unit 1 | Dryer Air Movement and Venting Systems | |
Unit 2 | Dryer Motors | |
Unit 3 | Dryer Air Temperature Control Systems | |
Unit 4 | Gas Burner Ignition Systems in Dryers | |
Unit 5 | Dryer Case Studies | |
Unit 6 | Common Problems in Gas Dryers | |
Module 8 | Gas Range Technology | |
Unit 1 | Gas Burner Spark Ignition Systems | |
Unit 2 | Gas Flame Detection | |
Unit 3 | Direct Spark Ignition Systems | |
Unit 4 | Gas Oven Hot Surface Ignition Systems | |
Module 9 | PSE&G Case Study 1: Dual Fuel Range - Gas Surface Burner Continuous Sparking | |
Unit 1 | Case Study 1: Problem Statement | |
Unit 2 | CS1: Schematic Review and Initial Findings | |
Unit 3 | CS1: Load of Interest | |
Unit 4 | CS1: LOI Circuit Analysis | |
Unit 5 | CS1: Troubleshooting Hypothesis | |
Unit 6 | CS1: Select Electrical Measurements & EEPs | |
Unit 7 | CS1: Make "Electrical" Measurements & Compare with Specs | |
Unit 8 | CS1: Case Study Wrap-up | |
Module 10 | PSE&G Case Study 2: Dual Fuel Range - Gas Surface Burner No Ignition | |
Unit 1 | Case Study 2: Problem Statement | |
Unit 2 | CS2: Schematic Review and Initial Findings | |
Unit 3 | CS2: Load of Interest | |
Unit 4 | CS2: LOI Circuit Analysis | |
Unit 5 | CS2: Troubleshooting Hypothesis | |
Unit 6 | CS2: Select Electrical Measurements & EEPs | |
Unit 7 | CS2: Make "Electrical" Measurements & Compare with Specs | |
Unit 8 | CS2: Case Study Wrap-up | |
Module 11 | PSE&G Case Study 3: Gas Range - Bake Burner No Ignition | |
Unit 1 | Case Study 3: Problem Statement | |
Unit 2 | CS3: Schematic Review and Initial Findings | |
Unit 3 | CS3: Load of Interest | |
Unit 4 | CS3: LOI Circuit Analysis | |
Unit 5 | CS3: Troubleshooting Hypothesis | |
Unit 6 | CS3: Select Electrical Measurements and Specifications | |
Unit 7 | CS3: EEPs for Electrical Measurements | |
Unit 8 | CS3: Make Electrical Measurements | |
Unit 9 | CS3: Compare Measurement Results to Specifications | |
Unit 10 | CS3: Case Study Wrap-up | |
Module 12 | PSE&G Case Study 4: Gas Range - Low/Erratic Oven Temperature | |
Unit 1 | Case Study 4: Problem Statement | |
Unit 2 | CS4: Schematic Review and Initial Findings | |
Unit 3 | CS4: Load of Interest | |
Unit 4 | CS4: LOI Circuit Analysis | |
Unit 5 | CS4: Troubleshooting Hypothesis | |
Unit 6 | CS4: Select Electrical Measurements and Specifications | |
Unit 7 | CS4: EEPs for Electrical Measurements | |
Unit 8 | CS4: Make Electrical Measurements | |
Unit 9 | CS4: Compare Measurement Results to Specifications | |
Unit 10 | CS4: Case Study Wrap-up |